An EV charging pile enclosure has to do three jobs at once, and they pull against each other: keep water out, get heat out, and stay standing in a public space day after day. The power rating decides which of the three dominates. At 7 kW AC the enclosure is mostly a sealed, weatherproof box with a cosmetic face. At 60–120 kW DC it becomes a thermal and structural problem, where the sealed-versus-vented trade-off has to be settled before the first panel is cut.

Key takeaways

  • Power class sets the design problem. A 7 kW AC wallbox is dominated by ingress and cosmetics; a 60–120 kW DC cabinet by heat rejection, cable management and structure. Do not reuse one enclosure architecture across both.
  • IP54 to IP55 for sheltered kerbside, IP65 where the site is hosed or takes driven rain, IP66 plus a corrosion specification on the coast. The rating and the corrosion specification are two lines, not one.
  • Airflow and ingress pull in opposite directions. Decide the vent area the thermal model needs first, then buy the IP rating that the vent, the drain and the gland can actually hold.
  • Most field failures are not rating failures. They are gasket compression at latch points, unrated cable glands, and condensation on the inside of the lid.
  • We fabricate the enclosure; we do not certify the charger. IK impact testing, electrical safety and product certification belong to your compliance path, not to the sheet metal drawing.

What does an EV charging pile enclosure actually have to do?

It holds the charger's power modules, control board, metering, cable management and connectors — and it does three things that compete:

Sealing harder helps the first and hurts the second. Cutting more vent area helps the second and hurts the first. Adding a sunshade helps the second and costs you a bracket and a fixings pattern. Every charging enclosure is a settlement between these three, and the settlement is different at every power level.

How does the power rating change the enclosure design?

This is the first question to answer, because it fixes the volume, the thermal strategy and the structure before any detail is drawn. The table below sets out the classes we see in RFQs most often. Where we have a production shell in that class we have linked it; the other rows describe typical market classes rather than our catalogue.

Power classTypical formWhat dominates the enclosure designThermal approachIngress targetStructure & hardware notes
3.7–7 kW AC (single-phase, ~32 A)Wallbox or slim pedestalCosmetics, sealing and cable storage. Heat is modest.Natural convection through screened vents or the enclosure skin itself.IP54 sheltered; IP55–IP65 exposedWall bracket or pedestal base, hinge plus latch, cable holster. See our 7 kW / 32 A AC charger enclosure.
11–22 kW AC (three-phase)Pedestal or wall-mountedMetering space, contactor and protective-device heat, cable management.Forced convection in most designs; filtered intake.IP55Heavier pedestal base, lockable service door, room for a meter and a terminal rail.
30–60 kW DCFloor-standing, single gunPower modules set the internal volume.Forced air with filtered intake and a directed exhaust path.IP54–IP55Module shelves or slides, lift points, earthing studs, a base that survives being set down on an uneven pad.
60–120 kW DCFloor-standing, dual gunHeat rejection, cable weight and frame stiffness.High-flow forced air with hot-aisle routing; a sunshade is usually worth costing.IP55Reinforced frame, dual cable management, heavy base, bonded door. See our 60–120 kW DC fast charger enclosure.
240 kW and above / hub architecturePower cabinet plus separate dispenser(s)Splitting the power stage away from the user interface.Cabinet: high-flow air or liquid. Dispenser: convection.IP55 cabinet; IP54–IP65 dispenser faceTwo enclosures, two specifications and one interconnect — the interface between them is where projects slip.

Two patterns are worth reading out of that table. The thermal approach changes before the form factor does, which means the vent and filter provisions — not the outline — are what you should freeze first. And above roughly 60 kW the cable, not the electronics, starts to set the structure: a heavy liquid-cooled or high-current cable hanging off one side applies a real moment to the frame, and the anchor point has to be designed for it rather than added afterwards. Our EV charger enclosure procurement guide walks through the sourcing side of the same decisions.

Which IP rating does an EV charger enclosure need?

IP codes are defined in IEC 60529 and cover ingress only — solids and dust in the first digit, water in the second. They say nothing about corrosion, impact or UV, which is why the "specify alongside" column below is not optional.

SiteRating we would specifyWhySpecify alongside it
Covered car park or indoor bayIP54Splash only. Here ventilation and vandal resistance matter more than ingress.Filtered vents, lockable service access, cosmetic class on the visible face.
Sheltered kerbside under a canopy or forecourt roofIP54–IP55Rain and light rinsing; the canopy does most of the work.Drain path at the base, breather vent rated to match.
Exposed urban kerbside (the common case)IP55Wind-blown dust plus a water jet — covers driven rain and a hose.Gasket material and compression hardware; cable glands rated to match.
Coastal or winter-salt siteIP66, plus 316 stainless or a marine-grade coating systemDriven salt spray behaves like a continuous jet, and salt is what kills the shell.Substrate, pretreatment and coating as an explicit line, with salt spray evidence. See our coastal charger material study.
Routine hose or pressure-wash cleaningIP66The IPX6 jet is the test that matches hose cleaning.Glands, vents and drains rated to match the shell.
Low-lying pad that can hold standing waterIP67, or a dual IP66/IP67Immersion, not jets. IP67 contains no jet test at all.Declared depth and duration on the datasheet; raised base or plinth.

The decoding of these digits — including why IP67 does not imply IP66 and why an unqualified IP68 claim is incomplete — is set out in our outdoor waterproof enclosure IP guide. If you also sell into North America, note that NEMA types and IP codes are not interchangeable: a NEMA type number bundles corrosion and icing requirements the IP code does not cover.

How do you cool a sealed charger enclosure without losing the rating?

This is the argument at the centre of every DC charger enclosure, and the order of operations matters. Start from the heat, not from the rating:

  1. Establish the heat to reject from your power stage and your worst-case ambient. That is your number, not ours.
  2. Remove what you can before it enters the box. A sunshade over the pile takes solar load off the shell before it becomes an internal air problem, and it is usually cheaper than the airflow needed to do the same job (see our sunshade and hood design guide).
  3. Decide the vent area and route. Intake low and filtered, exhaust high, and never discharging onto the user or the cable holster. Open area and hole pattern are sized from the airflow target — see the perforated vent pattern guide.
  4. Then buy the IP rating the vent can hold. A rated breather vent or a drain plug at the lowest point keeps liquid water out while letting pressure equalise. The failure mode to avoid is fitting a vent rated below the enclosure — that component becomes the enclosure's real rating.

Where the thermal model cannot be met with filtered air, the options are a sealed internal loop with an air-to-air heat exchanger, or a liquid path to a remote radiator. Both keep the rating intact because both keep the outside air outside; both cost more and add penetrations. Our thermal management guide and ventilation guide cover the geometry, and the condensation control guide covers what happens when a sealed box meets a cold wet night — which is the failure nobody models and everybody sees in the field.

What makes a public-space charger enclosure survive impact, vandalism and daily use?

None of this is in the IP code. Impact resistance has its own scale, the IK code defined in IEC 62262, and it is a separate line on the specification — an enclosure with no IK requirement has not been impact tested at all. IK10 sits at the top of that scale; what level you need depends on the site rather than on the product, and it is worth asking your insurer before you ask your fabricator (see our IK rating guide).

The rest is hardware and detail. Hinges and latches carry the door every day for a decade, and that is a specification in its own right rather than a catalogue pick (see the hinge and latch hardware guide). Recessed or tamper-resistant fasteners, a lock that survives being forced in the rain, and a door stiff enough not to bow between latch points all matter. For exposed unattended sites, our vandal resistant design guide goes through the details that actually change outcomes.

Earthing is the one that gets missed. A powder-coated door on a powder-coated frame does not make a bonding path. Grounding continuity has to be designed in — a stud, a bonded hinge, a toothed washer at a defined location — and it belongs on the drawing, not in the assembly note. See our grounding and bonding guide.

Which materials and finishes hold up on a kerbside site?

Most charging enclosures are cold-rolled steel for strength and cost, with galvanized or stainless steel where corrosion governs and aluminium where weight does. The pattern we see:

Whichever substrate you choose, the finish is a system — pretreatment, coating and cure — and the common failure is specifying "powder coated" and expecting the coating to compensate for a substrate that was wrong for the site. Our material selection guide and corrosion resistance and coatings guide cover the trade-offs; the salt spray testing guide explains how coating claims are evidenced. On a branded product, also decide which faces carry which cosmetic class — a charger that only ever shows its front does not need an A-class finish on all six sides (see the cosmetic surface class guide).

How is a charging pile enclosure built, and which steps decide the outcome?

Through the same controlled sequence as any sheet metal assembly: DFM review, laser cutting, CNC bending, forming, welding, grinding and deburring, hardware insertion, powder coating, assembly and inspection — set out in full in our nine-step fabrication process. Four steps decide whether the rating survives production. Welding and grinding decide whether seams can be sealed at all. Deburring decides whether gaskets seat — a burr under a gasket is a leak. Bending accuracy decides whether the door compresses the gasket evenly along its whole length. Assembly decides whether the specified glands, latches and earth hardware are fitted and torqued.

That last point is where kerbside products usually fail. A cabinet designed to IP66 and assembled with one unrated cable gland is not an IP66 cabinet; the assembly is only as good as its weakest rated component. Cable entry is worth specifying explicitly rather than leaving to the installer — see our cable gland selection guide.

What should go on the RFQ?

Put the three duties on the request as separate requirements. Then add:

SanJun runs nine processes in-house across a 5,000 m² facility under ISO 9001 and ISO 14001, with RoHS and REACH compliance, a one-piece minimum order and free CAD and DFM review. Standard parts ship in 7–15 working days and custom builds in 20–30 days; sample lead time is quoted by complexity rather than as one headline number, because a flat sample panel and a welded, coated prototype cabinet are different jobs. See our EV charging enclosures for the range we build, our enclosure lead time guide for what moves the schedule, and the custom enclosure cost guide for what moves the price.

Frequently Asked Questions

Is IP65 enough for an outdoor EV charger?

For most exposed kerbside sites, yes — IP65 covers rain, wind-blown dust and hose-down, which is what a charger on a street actually faces. Step up to IP66 where the site takes driven salt spray or is routinely pressure washed, and only consider IP67 where the pad can hold standing water — and remember that IP67 is an immersion test with no jet test, so where a site faces both, specify a dual rating such as IP66/IP67. If the site is coastal, the rating is the easy half: the corrosion specification is the half that decides service life.

Does a higher IP rating make the charger more reliable?

Not necessarily, and pushing the rating without touching the thermal design is a common way to make a charger less reliable. Sealing harder traps heat and traps moisture — the condensation that forms on the inside of a lid on a cold night is a failure mode that a higher IP rating does nothing about and can make worse. There is a second trap: an enclosure is rated as an assembly, so its real rating is the rating of its weakest component. One unrated cable gland turns an IP66 cabinet into an unrated cabinet.

Can a sealed enclosure still be cooled?

Yes, but not with outside air. The options are a sealed internal loop with an air-to-air heat exchanger on the shell, or a liquid path to a remote radiator. Both keep outside air out and so keep the rating intact; both cost more and add penetrations that have to be sealed. Before paying for either, cost the passive options: a sunshade to take the solar load off the shell, a filtered vent with a rated breather, and an internal layout that does not trap the heat where the modules are.

Do I need an IK rating, and what is it?

You need one if the charger can be struck, kicked or hit by a vehicle, and an IP rating does not cover it. IK is the impact protection code defined in IEC 62262 and it is a separate line on the specification: an enclosure quoted without an IK level has not been impact tested. IK10 sits at the top of the scale. Which level you need is a site and insurance question rather than a fabrication question, so settle it before the drawing is frozen rather than after the first unit is damaged.

Galvanized steel or 316 stainless for a coastal charger?

It depends on how close to the sea and on the service life you are selling. Galvanized steel adds sacrificial protection at cut edges and scratches at modest cost and suits most general outdoor and humid inland sites. Where chlorides are present — coastal air, winter de-icing salt — 316 stainless is the specification, because it is the molybdenum-bearing grade. Powder-coated carbon steel is the option we would argue against on a seafront. Our coastal charger material study works through the same decision with numbers.

Does powder coating alone stop corrosion?

No. Coating is a system — pretreatment, coating and cure — and it protects a substrate, it does not replace one. A scratched powder-coated carbon-steel enclosure on a coastal site rusts at the scratch, and a coating applied over poor pretreatment fails at the edges long before it fails in the middle. Specify substrate, pretreatment, coating system and the evidence you want (a salt spray result, for example) as separate line items, and choose the substrate for the site first.

How do cables enter without breaking the rating?

Through a gland or conduit entry rated to at least the enclosure's own level, matched to the cable diameter, on a flat entry plate that stays flat when the gland is torqued. The charge cable itself deserves the same attention: it carries water into the holster and applies a real moment to the frame, so the anchor point and the drain path are design items. See our cable gland selection guide.

What is the lead time, and what is the minimum order?

Minimum order quantity is one piece, and CAD and DFM review are free. Standard parts ship in 7–15 working days and custom builds in 20–30 days. Sample lead time is quoted by complexity rather than as one headline number — a flat sample panel, a welded frame and a fully coated prototype are three different jobs with three different schedules. The fastest route is usually to send the model and let us come back with a manufacturability note before you freeze the drawing.

Developing a charging product? Send your specifications for a quote within 24 hours.

The payment and status screen faces sun, impact and cleaning at once; material, thickness and sealing for that one square are set out in our enclosure viewing window glazing guide.

The industry constraints behind this design, and the commercial side of buying it, are collected in the applications and sourcing cluster.

充电桩外壳要同时完成三项任务,而这三项彼此牵制:把水挡在外面、把热量排出去,并且日复一日地立在公共空间里。功率等级决定哪一项占主导。7 kW 交流场景下,外壳主要是一个带外观面的密封防雨箱体;到 60–120 kW 直流,它变成一个热与结构问题,密封与通风的取舍必须在第一块板下料之前就定下来。

核心要点

  • 功率等级决定了设计问题本身。7 kW 交流壁挂桩由防护与外观主导;60–120 kW 直流柜由散热、线缆管理与结构主导。不要用一个外壳架构横跨两者。
  • 有遮挡的路边用 IP54–IP55,会被冲洗或直面暴雨的用 IP65,沿海用 IP66 并另加耐腐蚀规格。等级与耐腐蚀是两条规格,不是一条。
  • 通风与防护方向相反。先按热模型定下所需的通风面积,再去买那个通风口、排水塞与格兰头真能守住的 IP 等级。
  • 多数现场失效不是等级失效。它们是锁扣处的胶条压缩量不足、未评级的电缆格兰头,以及顶盖内侧的凝露。
  • 我们制造外壳,不做整机认证。IK 抗冲击试验、电气安全与产品认证属于你的合规路径,不属于钣金图纸。

充电桩外壳究竟要做什么?

它容纳充电器的功率模块、控制板、计量、线缆管理与连接器,并完成三项彼此竞争的任务:

密封做得更严,帮的是第一项、害的是第二项。多开通风面积,帮的是第二项、害的是第一项。加一个遮阳罩,帮的是第二项,代价是一套支架与紧固孔位。每台充电外壳都是这三者之间的和解协议,而每个功率等级上的和解方式都不一样。

功率等级如何改变外壳设计?

这是第一个要回答的问题,因为它决定了容积、散热策略与结构形式,然后才有细节。下表列出了询价中最常见的功率档次;我们在该档次有量产外壳的地方放了链接,其余各行描述的是市场常见档次,而非我们的目录。

功率档次典型形态外壳设计的主导因素散热方式防护目标结构与五金要点
3.7–7 kW 交流(单相,约 32 A)壁挂式或细立杆外观、密封与线缆收纳。热量不大。通过带防虫网的通风口或壳体自身自然对流。有遮挡 IP54;暴露 IP55–IP65壁挂支架或立杆底座、铰链加锁扣、充电枪挂座。参见我们的7 kW / 32 A 交流充电桩外壳。
11–22 kW 交流(三相)立杆式或壁挂式计量空间、接触器与保护器件发热、线缆管理。多数设计为强制对流;带滤网进风。IP55更重的立杆底座、可锁检修门、为电表与端子导轨留出空间。
30–60 kW 直流落地式,单枪功率模块决定内部容积。强制风冷,带滤网进风与定向排风路径。IP54–IP55模块托板或滑轨、吊点、接地螺柱,以及能承受落在不平整基础上冲击的底座。
60–120 kW 直流落地式,双枪散热能力、电缆重量与框架刚度。大风量强制风冷加热通道导流;遮阳罩通常值得计入成本。IP55加强框架、双路线缆管理、加厚底座、门板跨接接地。参见我们的60–120 kW 直流快充桩外壳。
240 kW 及以上/充电枢纽架构功率柜 + 独立终端把功率级与人机界面分离。功率柜:大风量风冷或液冷;终端:自然对流。功率柜 IP55;终端正面 IP54–IP65两台外壳、两份规格、一套互联——项目滑期的正是两者之间的接口。

这张表里有两条规律值得读出来。散热方式先于外形尺寸发生变化,这意味着你应该先冻结的是通风与滤网条款,而不是轮廓。而超过约 60 kW 之后,开始决定结构的是电缆而不是电子件:一根沉重的液冷或大电流电缆挂在一侧,会对框架施加真实的力矩,锚固点必须为此设计,而不是事后补上。我们的充电桩外壳采购指南从采购角度走了一遍同样的决策。

充电桩外壳需要哪个 IP 等级?

IP 代码由 IEC 60529 定义,只管进入防护——第一位数字管固体异物与粉尘,第二位管水。它对腐蚀、抗冲击与紫外老化未作任何说明,这正是下表"须同时指定"一栏不可省略的原因。

现场我们会指定的等级理由须同时指定
有顶棚的停车场或室内车位IP54只有溅水。此处通风与防破坏比进入防护更重要。带滤网通风口、可锁检修口、可见面的外观等级。
雨棚或站房屋檐下的有遮挡路边IP54–IP55降雨与轻度冲洗;雨棚已承担大部分工作。底部排水路径、与本体同等级的呼吸阀。
无遮挡的城市路边(最常见)IP55风吹粉尘加喷水试验——覆盖强降雨与水管冲洗。胶条材料与压紧五金;同等级电缆格兰头。
沿海或冬季撒盐区域IP66,另加 316 不锈钢或船用级涂层体系强海风盐雾在效果上等同于持续喷射,而真正杀死外壳的是盐。基材、前处理与涂层作为独立条目,并附盐雾试验证据。参见我们的沿海充电桩材料研究。
需常规水管或高压水枪清洗IP66IPX6 喷射试验才对应水管冲洗这种工况。与外壳同等级的格兰头、呼吸阀与排水塞。
可能积水的低洼基础IP67,或 IP66/IP67 双等级风险是浸水而非喷射。IP67 完全不含喷射试验。把声明的深度与时长写进数据表;抬高底座或加基座。

这些数字的完整解读——包括为什么 IP67 并不蕴含 IP66、以及为什么不带条件的 IP68 声明是不完整的——见我们的户外防水外壳 IP 等级指南。如果你同时销售到北美,请注意NEMA 类型与 IP 代码不能互换:NEMA 类型号把耐腐蚀与结冰等 IP 体系未覆盖的要求捆绑在同一个编号里。

如何在不丢失防护等级的前提下给密封充电桩散热?

这是每台直流充电外壳设计中的核心争论,而操作顺序很重要。从热量出发,而不是从等级出发:

  1. 确定需要排掉的热量——来自你的功率级与最恶劣环境温度。这是你的数字,不是我们的。
  2. 在热量进入箱体之前先削掉一部分。给桩体加遮阳罩,能在太阳负荷变成内部空气问题之前就把它挡在壳体外,而且通常比用风量做同样的事更便宜(参见遮阳罩与防雨帽设计指南)。
  3. 确定通风面积与路径。低位带滤网进风、高位排风,且绝不朝向用户或充电枪挂座排放。开孔率与孔型按气流目标计算——参见定制穿孔通风模式指南。
  4. 然后去买通风口真能守住的 IP 等级。同等级的呼吸阀或位于最低点的排水塞,可以在阻挡液态水的同时让压力平衡。需要避免的失效模式是:装上等级低于外壳本体的阀——那样该零件就成了外壳的真实等级。

如果热模型靠过滤空气无法满足,可选方案是带气-气换热器的密封内循环,或通往远端散热器的液冷路径。两者都能保住等级,因为两者都把外部空气留在外部;两者成本更高,也都会增加需要密封的穿孔。外壳热管理指南与通风设计指南讲几何,凝露控制指南讲密封箱体遇到寒冷潮湿夜晚时会发生什么——那正是没人建模、却人人在现场看到的失效。

公共空间的充电外壳靠什么扛住冲击、破坏与日常使用?

这些都不在 IP 代码里。抗冲击有它自己的标度——由 IEC 62262 定义的 IK 代码——它是规格上独立的一条;一台没有 IK 要求的外壳,根本没有做过抗冲击试验。IK10 位于该标度的顶端;你需要哪一级取决于现场而不是产品,而且值得先问保险公司再问制造商(参见IK 抗冲击等级指南)。

其余的是五金与细节。铰链与锁扣要在这十年里天天承受门板,它本身就是一项规格,而不是从样本册上随便挑一个(参见铰链与锁扣五金指南)。沉头或防拆紧固件、一把在雨中被撬也扛得住的锁,以及一块刚度足够、不会在锁扣之间鼓起的门板,都很重要。对无遮挡、无人值守的现场,我们的防破坏设计指南逐项说明了真正能改变结果的细节。

最容易漏掉的是接地。喷粉门板装在喷粉框架上,并不能形成搭接通路。接地连续性必须是设计出来的——一颗接地螺柱、一副跨接铰链、或在指定位置使用齿形垫圈——并且它属于图纸,而不是装配说明。参见接地与跨接设计指南。

路边现场该用哪些材料与表面处理?

多数充电外壳用冷轧钢换取强度与成本,在腐蚀成为主导因素处用镀锌板或不锈钢,在重量成为主导因素处用铝材。我们常见的格局如下:

无论选哪种基材,涂层都是一个体系——前处理、涂料与固化——而最常见的失效是只写"粉末喷涂"四个字,却指望涂层去弥补一个本就不适合该现场的基材。我们的钣金材料选型指南与耐腐蚀与涂层指南讲取舍,盐雾试验指南说明涂层声明该如何取证。对于带品牌外观的产品,还要决定哪几个面采用哪一级外观等级——一台只有正面会被看到的充电桩,不需要六个面都做 A 级(参见外观表面等级指南)。

充电桩外壳是怎么造出来的,哪几步决定结果?

通过与任何钣金组件相同的受控工序:DFM 评审、激光切割、数控折弯、成形、焊接、打磨去毛刺、五金植入、粉末喷涂、装配与检验——完整内容见九步钣金加工工艺。其中四道工序决定了防护等级能否在量产中保住。焊接与打磨决定接缝是否具备可密封的前提。去毛刺决定胶条能否贴合——胶条下方的一处毛刺就是一条漏水通道。折弯精度决定门板能否沿整条边均匀压缩胶条。装配决定规定型号的格兰头、锁扣与接地五金是否真的装上并拧到规定扭矩。

最后一点正是路边产品通常失效的地方。一台按 IP66 设计、却装了一个未评级电缆格兰头的机柜,不是 IP66 机柜;整机的等级等于其最弱零件的等级。电缆入口值得明确指定,而不是留给安装方——参见电缆格兰头选型指南。

询价单上该写什么?

把三项职责作为独立要求写进询价单,然后补充:

三骏在 5,000 ㎡ 厂房内自制九道工序,持有 ISO 9001 与 ISO 14001 认证,符合 RoHS 与 REACH,1 件起订,免费提供 CAD 与 DFM 评审。标准件 7–15 个工作日交付,定制件 20–30 天;样品交期按复杂度分档报价,而不是给一个统一数字,因为一块平板样品与一台完成喷涂的样机柜是两种不同的工作。我们制造的范围见充电桩外壳;什么会推动排程见外壳交期指南;什么会推动价格见定制钣金外壳成本指南。

常见问题

户外充电桩用 IP65 够吗?

对多数无遮挡的路边点位而言够了——IP65 覆盖降雨、风吹粉尘与水管冲洗,这正是街边充电桩真正面对的工况。只有当现场会遭遇强海风盐雾或常规高压清洗时才升到 IP66;只有当基础可能积水时才考虑 IP67——而且请记住,IP67 是浸水试验、完全不含喷射试验,因此当现场两者都要面对时,应指定 IP66/IP67 这类双等级。如果现场在沿海,等级是容易的那一半:决定服役寿命的是耐腐蚀规格。

IP 等级越高,充电桩就越可靠吗?

不一定,而且在不改热设计的前提下硬推等级,是让充电桩变得更可靠的反面——一种常见做法。密封更严会困住热量,也会困住湿气:寒冷夜晚在顶盖内侧形成的凝露,是一种更高 IP 等级既解决不了、还可能加剧的失效模式。还有第二个陷阱:外壳是作为整机被评级的,因此它的真实等级等于最弱零件的等级。一个未评级的电缆格兰头,就能把一台 IP66 机柜变成一台没有等级的机柜。

全密封外壳还能散热吗?

能,但不能靠外部空气。可选方案是在壳体上装气-气换热器的密封内循环,或通往远端散热器的液冷路径。两者都把外部空气留在外部,因而都能保住等级;两者成本更高,也都会增加需要密封的穿孔。在为任何一项付钱之前,先把被动方案计入成本:用遮阳罩把太阳负荷挡在壳体外、用带滤网的通风口配同等级呼吸阀,以及一个不会把热量困在模块所在位置的内部布局。

我需要 IK 等级吗?它是什么?

如果充电桩可能被撞、被踢或被车辆碰到,就需要——而 IP 等级并不覆盖这一点。IK 是由 IEC 62262 定义的抗冲击防护代码,它是规格上独立的一条:一台报价里没有 IK 等级的外壳,根本没有做过抗冲击试验。IK10 位于该标度的顶端。你需要哪一级是现场与保险问题,而不是制造问题,因此请在图纸冻结之前定下来,而不是在第一台设备被砸坏之后。

沿海充电桩用镀锌钢还是 316 不锈钢?

取决于离海多近,以及你承诺的服役年限。镀锌钢以不大的成本增幅在切割断面与划伤处提供牺牲阳极保护,适合多数一般户外与潮湿内陆现场。存在氯化物的场合——沿海空气、冬季融雪盐——应指定 316 不锈钢,因为它是含钼牌号。在海滨现场,我们会主张不要选粉末喷涂碳钢。我们的沿海充电桩材料研究用数字走了一遍同样的决策。

光靠粉末喷涂就能防腐蚀吗?

不能。涂层是一个体系——前处理、涂料与固化——它保护基材,而不能替代基材。一台划伤的粉末喷涂碳钢外壳在沿海现场会从划痕处开始生锈,而涂在前处理不良表面上的涂层,边缘失效远早于中间失效。请把基材、前处理、涂层体系与你想要的证据(例如盐雾试验结果)分列成独立条目,并且先按现场选基材。

电缆怎样引入才不破坏防护等级?

通过与外壳本体等级相当或更高的格兰头或线管入口,按电缆外径选型,装在拧紧后仍保持平整的入口板上。充电电缆本身值得同样的关注:它会把水带进挂座,也会对框架施加真实的力矩,因此锚固点与排水路径都是设计项。参见电缆格兰头选型指南。

交期多久,起订量是多少?

最低起订量为 1 件,CAD 与 DFM 评审免费。标准件 7–15 个工作日交付,定制件 20–30 天。样品交期按复杂度分档报价,而不是给一个统一数字——一块平板样品、一个焊接框架与一台完成喷涂的样机是三种不同工作,排程也不同。通常最快的路径是把模型发过来,让我们先出一份可制造性意见,你再冻结图纸。

正在开发充电产品?发送规格,24 小时内获取报价。

支付屏与状态屏要同时面对日照、冲击和清洁;这一小块面积的材料、厚度与密封见我们的外壳观察窗玻璃设计指南。

这个设计背后的行业约束,以及采购侧的要点,收在行业应用与采购专题里。

Developing an EV Charging Product?正在开发充电产品?

Send us your specifications and get a quotation within 24 hours.发送你的规格,24 小时内获取报价。